Victron Cyrix-Li-Charge Intelligent Charge Relay 12/24V -120A
CYR010120430 5 Year Warranty
Sign up to be the first to know when it's here
Victron Cyrix-Li-Charge Intelligent Charge Relay 12/24V -120A est en rupture de stock et sera expédié dès qu’il sera de retour en stock.
Impossible de charger la disponibilité pour le Service de retrait
FAST FREE UK STANDARD SHIPPING*
FAST FREE UK STANDARD SHIPPING*
• Express delivery £7.99 (Monday-Friday, orders placed before 1pm)
• Click here for more delivery information
60 DAY NO QUIBBLE RETURNS
60 DAY NO QUIBBLE RETURNS
• 60 days hassle-free returns. - exclusions apply
Description
Description
The Cyrix-Li-Charge will connect a battery charger with 3 seconds delay:
- if the charge disconnect output of the VE.Bus BMS is high, and
- if it senses 13.0 V (resp. 26.0 V) or more on its battery charger connection terminal, and
- if it senses 2 V or more on its battery terminal
(the Cyrix will remain open if not connect to the battery)
The Cyrix-Li-Charge will disengage immediately whenever its control input becomes free floating, signalling cell over voltage or cell over temperature.
In general, a cell over voltage alarm will reset shortly after charging has been stopped. The Cyrix will then reconnect the charger after a delay 3 seconds
When the Cyrix-Li-Charge is engaged (charger connected to battery) it will disengage after 1 hour to check if the charger is still enabled..
If, after the Cyrix has disengaged, the output of the battery charger immediately increases to 13.0 V or more, the Cyrix will reengage, with a 3 seconds delay.