Collect PROTEUS POINTS on every purchase. Learn more

Victron Cyrix-Li-Charge 24 / 48V 230A Intelligent Charge Relay

Scrivi una recensione
| Fai una domanda

CYR020230430 5 Year Warranty

£150.80 £194.40

FAST FREE UK STANDARD SHIPPING*

• Express delivery £7.99 (Monday-Friday, orders placed before 1pm)

• Click here for more delivery information

60 DAY NO QUIBBLE RETURNS

• 60 days hassle-free returns. - exclusions apply

Descrizione

The Cyrix-Li-Charge will connect a battery charger with 3 seconds delay:

  • if the charge disconnect output of the VE.Bus BMS is high, and
  • if it senses 13.7 V (resp. 27.4 V or 54.8 V) or more on its battery charger connection terminal, and
  • if it senses 2 V or more on its battery terminal (the Cyrix will remain open if not connect to the battery).

The Cyrix-Li-Charge will disengage immediately whenever its control input becomes free floating, signalling cell over voltage or cell over temperature.

In general a cell over voltage alarm will reset shortly after charging has been stopped. The Cyrix will then reconnect the charger after a delay 3 seconds. After 2 attempts to reengage with 3 seconds delay, the delay increases to 10 minutes. Whenever battery voltage is less than 13.5 V (resp. 27 V or 54 V), the Cyrix will disengage with a delay of 1 hour.

Datasheet

Features

o Voltage: 24/48
Continuous current & Breaking capacity at 12V or 24V: 230A
o Current Consumption When Open: 4 mA
o Control Cable Included: Yes, (1m)
o LED Status Indication: Yes
o Protection Category: IP54
o Dimensions: 65 x 100 x 50mm
o Weight: 0.27Kg

Specifications

N/A (Not Applicable)

Victron Cyrix-Li-Charge 24 / 48V 230A Intelligent Charge Relay - PROTEUS MARINE STORE
Victron

Victron Cyrix-Li-Charge 24 / 48V 230A Intelligent Charge Relay

£150.80 £194.40

The Cyrix-Li-Charge will connect a battery charger with 3 seconds delay:

  • if the charge disconnect output of the VE.Bus BMS is high, and
  • if it senses 13.7 V (resp. 27.4 V or 54.8 V) or more on its battery charger connection terminal, and
  • if it senses 2 V or more on its battery terminal (the Cyrix will remain open if not connect to the battery).

The Cyrix-Li-Charge will disengage immediately whenever its control input becomes free floating, signalling cell over voltage or cell over temperature.

In general a cell over voltage alarm will reset shortly after charging has been stopped. The Cyrix will then reconnect the charger after a delay 3 seconds. After 2 attempts to reengage with 3 seconds delay, the delay increases to 10 minutes. Whenever battery voltage is less than 13.5 V (resp. 27 V or 54 V), the Cyrix will disengage with a delay of 1 hour.

Datasheet

Visualizza prodotto